Modern mines demand electrical systems that are reliable under movement, abrasion, moisture, and long duty cycles. When mobile machines must be fed with stable power in challenging conditions, the right choice of cable minimizes downtime, reduces maintenance, and protects personnel. The MYP 1.9/3.3kV cable is a purpose-built solution that balances flexibility, mechanical resilience, and electrical integrity for power distribution in mid-voltage mining applications.
This cable family is designed for movable and semi-mobile equipment whose power demands exceed basic low-voltage feeders but do not require full medium-voltage cabling systems. In practical terms, the MYP 1.9/3.3kV cable offers an excellent blend of conductor performance, insulating chemistry, and robust jacketing that supports reeling, trailing, and fixed feeder uses in underground and surface mining operations.
The 1.9/3.3kV rating sits in a practical band for many coal-cutting, excavation, and haulage machines. It allows efficient power delivery to larger motors and drives while keeping cable handling and termination simpler than true medium-voltage systems. For operations that need higher power but still want flexible power leads, the MYP 1.9/3.3kV cable bridges that gap—delivering current capacity and mechanical properties tailored to heavy-duty mobile equipment.
A reliable MYP 1.9/3.3kV cable has several engineered layers, each contributing to mechanical and electrical performance:
Flexible conductors — The cable uses finely stranded copper conductors that tolerate repeated bending without strand breakage. For corrosion-prone environments, tinned copper options extend service life.
Insulation system — Elastomeric insulating compounds such as EPR or specialized mining rubbers preserve dielectric strength while resisting thermal aging and chemical exposure. These materials stay flexible across operational temperature ranges to avoid cracking under mechanical stress.
Metallic screening — A continuous copper wire braid or tinned copper screen provides controlled grounding behavior and reduces electromagnetic interference when power and control circuits share proximity. This is important for instrumentation reliability on modern equipment.
Rugged outer sheath — The jacket is formulated for abrasion resistance, oil and water resistance, and flame performance when required. Typical sheath compounds include chlorinated polyethylene, neoprene, or low-smoke, halogen-free rubbers depending on the application and safety requirements.
Together, these layers make the MYP 1.9/3.3kV cable able to survive dragging, reeling, and the incidental rough handling that characterizes mining sites.
This cable family addresses a range of operational needs:
Powering larger face mining machines and shearers where higher motor currents require more robust conductors than low-voltage trailing cables.
Reeling drums and spooled power lines that must flex repeatedly while remaining electrically stable.
Trailing power to loaders, conveyors and mobile drilling units that see continual movement and abrasion.
Temporary high-capacity power layouts during maintenance or restructuring where flexible but high-capacity cables are required.
Feeder lines for ventilation and pumping systems that demand both mechanical toughness and higher current capacity.
In each of these uses, the cable’s construction reduces cable-related failures and simplifies maintenance planning.

Choosing the right cable variant begins with matching the electrical and mechanical profile of the application:
Rated voltage and current capacity — Confirm the cable’s U0/U rating and choose conductor cross-section to carry the expected continuous load with acceptable temperature rise. Overspecify by a margin if peak currents or surges are expected.
Conductor stranding and plating — Where flexibility is paramount, select fine-stranded conductor classes; in corrosive or wet conditions prefer tinned strands.
Insulation & jacket materials — For wet or oil-contaminated galleries, choose compounds with proven resistance to hydrocarbon exposure. For underground use requiring fire safety, opt for low-smoke, halogen-free jackets if regulations or evacuation considerations demand it.
Shielding & earthing — If automated control systems are present, select screened constructions and ensure the earthing strategy accounts for screen bonding and fault paths.
Mechanical protection — Where crushing or severe impact is possible, consider armored options or reinforced jackets—balanced against the need for flexibility.
Factory testing & certification — Require documented tests for insulation resistance, high-voltage withstand, bending cycle fatigue, and any mining authority acceptances relevant to your jurisdiction.
Even the best MYP 1.9/3.3kV cable needs conscientious installation to perform as designed:
Respect minimum bend radius to prevent conductor stress and insulation deformation.
Provide strain relief at terminations to keep tensile loads off conductor joints.
Route to avoid sharp edges and concentrated abrasion; use rounded guides and protective sleeves where needed.
Ensure proper sealing at connectors to avoid moisture ingress and contamination.
Document runs and label terminations so maintenance crews can quickly identify circuits during service.
These practices extend cable life and reduce unplanned outages.
A planned inspection routine preserves value and safety:
Frequent visual checks for jacket abrasion, cuts, or kinks.
Thermographic checks at terminations to spot resistive heating early.
Periodic insulation resistance testing to track degradation.
Replacement thresholds based on measurable wear indicators rather than catastrophic failure.
Predictive maintenance reduces emergency repairs, prevents collateral equipment damage, and keeps production schedules stable.
A trustworthy supplier will provide factory test certificates that include dielectric tests, insulation resistance, and bending/fatigue evidence. Where applicable, reference to mining standards and authority acceptance simplifies procurement approvals. For installations with strict safety requirements, select cables whose test reports show compliance with recognized mining or electrical safety protocols.
Selecting a supplier is more than buying cable on price. Evaluate:
Test and quality documentation — traceable evidence of manufacturing tests and material specs.
Support for acceptance testing — on-site assistance or clear acceptance test procedures.
Warranty and spare availability — pragmatic warranty terms and the ability to source spares quickly reduce operational risk.
Field references — operators who have similar installations can validate real-world performance claims.
High-quality MYP 1.9/3.3kV cable typically costs more up front, but lower lifecycle costs from fewer replacements and less emergency labor usually justify the investment.
On sites where the proper mid-voltage flexible cable was specified and installed, maintenance teams report fewer conductor failures and lower incidence of splices and emergency replacements. Reeling applications that used a tested 1.9/3.3kV formulation experienced longer spool life and more predictable maintenance intervals, enabling better production planning and fewer unscheduled stoppages.
In mining operations the cable linking transformers and machinery is far from a passive component—it directly affects safety, uptime, and operating cost. When your application needs a balance of higher power and flexibility, the MYP 1.9/3.3kV cable offers a proven technical approach: flexible conductors, resilient insulation, effective screening, and rugged jacketing engineered for the realities of mining.
Specify clearly, install carefully, inspect regularly, and choose suppliers who back their product with test data and field support. Doing so turns a cable purchase into a strategic investment that delivers reliable power, safer operations, and measurable lifecycle savings.