A request for 4 core 120mm2 or 4 core 185mm2 XLPE cable identifies core count and nominal area, but still leaves several price-critical fields open. Confirm the conductor, voltage, armour, sheath, standard and quantity before treating two supplier quotations as equivalent.
A 4 core 120mm2 XLPE cable supplier needs more than a size in the enquiry title. Specify conductor material, voltage, armour, sheath and whether every core has a nominal area of 120mm2.
Ask the 4 core 120mm2 XLPE cable supplier to supply dimensions and electrical data for the proposed construction. The responsible designer should verify suitability against the actual load, route and protection requirements.
When reviewing a 4 core 120mm2 XLPE cable supplier, compare the same quantity, drum lengths and acceptance documents. Keep proposed alternatives separate until the project team has approved them.
Send the 4 core 120mm2 XLPE cable supplier the approved schedule revision and destination with your RFQ. Ask for itemised pricing and confirmation of construction availability before agreeing an order.
In an equal-core notation, 4x120 mm² means four conductors each with a nominal area of 120 mm²; 4x185 mm² means four at 185 mm². The number is an area, not a diameter. State any unequal neutral or protective-conductor arrangement explicitly rather than abbreviating it as “4 core”.
| Specification field | 4x120 enquiry | 4x185 enquiry |
|---|---|---|
| Rated voltage | State the required U0/U | State the required U0/U |
| Conductor | Copper or aluminium; class and shape | Copper or aluminium; class and shape |
| Insulation / sheath | XLPE and the specified sheath | XLPE and the specified sheath |
| Armour | Unarmoured, STA or SWA as approved | Unarmoured, STA or SWA as approved |
| Installation | Approved route and calculation reference | Approved route and calculation reference |
| Order | Metres, drum plan, destination | Metres, drum plan, destination |
A larger nominal area does not by itself settle the project choice. Check the approved current capacity, voltage drop, fault duty, terminal capacity and route constraints. Eland’s sizing guidance identifies current capacity, voltage regulation and short-circuit performance as key selection factors. Ask the project engineer to approve any alternative size.
A 4 core 185mm2 armoured cable quotation should identify conductor material and armour type as well as the nominal core area. A four-core description should not conceal a reduced neutral or a different arrangement.
Review the 4 core 185mm2 armoured cable quotation against the project-approved cable schedule. Confirm the insulation, sheath and required standard before comparing commercial terms with another offer.
Ask whether the 4 core 185mm2 armoured cable quotation includes the proposed drum lengths, packing and inspection scope. Reconcile delivered metres and permissible length tolerances in the order documents.
To request a firm 4 core 185mm2 armoured cable quotation, provide quantity, destination and the required shipment window. Keep engineering approval separate from the commercial choice of supplier.
For larger multi-core cables, obtain overall diameter, approximate mass, bending radius and the manufacturer’s pulling instructions. Check drum dimensions and weights against unloading equipment and site access. The installation team may need a continuous length that differs from a supplier’s standard production or transport preference.
Keep cut-length allowances and spare metres visible in the BOQ. Ask how individual drum lengths, length tolerances and any permitted joints will be documented. Do not split a long run into shorter drums solely to reduce freight without project approval.
A 4 core 185mm2 armoured cable price enquiry for a UAE project, for example, should state the destination and delivery scope along with the technical schedule. Ask for price validity, quantity basis, packing, inspection costs and production lead time. Compare a local-delivery offer and an export-shipment offer only after accounting for their different scope.
Do not assume a fixed conversion. Submit the proposed design for electrical, connection and installation review.
No. Specify steel wire or steel tape and check the offered drawing.
Availability, minimum quantity and lead time require a current written offer for the exact construction.
Keep the LV cable enquiry linked to the approved specification revision. Ask for the proposed LV cable datasheet before comparing commercial offers. Record any LV cable substitution as a separate item for technical approval.
Browse the 0.6/1kV low voltage power cable range and send Honglin Cable your project enquiry. Include the approved LV cable schedule, standard, conductor, core sizes, construction, total metres and destination. Attach the approved 4x120 or 4x185 schedule and requested drum lengths. Ask for a specification-specific datasheet and a written quotation confirming available construction, minimum quantity, production lead time and delivery scope.